Interferential Therapy Unit

The basic principle of Electrotherapy Interferential Therapy Machine (IFT) is to utilise the strong physiologicaportable interferential effects of low frequency (<250pps) electrical stimulation of nerves without the associated painful and somewhat unpleasant side effects sometimes associated with low frequency stem.

To produce low frequency effects at sufficient intensity at depth, patients can experience considerable discomfort in the superficial tissues (i.e. the skin). This is due to the impedance of the skin being inversely proportional to the frequency of the stimulation. In other words, the lower the stimulation frequency, the greater the impedance to the passage of the current & so, more discomfort is experienced as the current is ‘pushed’ into the tissues against this barrier. The skin impedance at 50Hz is approximately 3200* whilst at 4000Hz it is reduced to approximately 40*. The result of interferential machines applying a higher frequency is that it will pass more easily through the skin, requiring less electrical energy input to reach the deeper tissues & giving rise to less discomfort.

Interferential Therapy + TensCode: LCS 145
SPECIFICATIONS
DIMENSION (L*H*D) 410mm, 115mm, 330mm
WEIGHT 4 Kg. Approx.
OPERATING VOLTAGE 140 ~ 270V AC, 50Hz
ABSORPTION 46-Watts Max
FUSES 1 Amp
ROOM TEMPERATURE 10° to 40° C
MOISTURE 10% to 80%
PROGRAM 25 Present Programs
MANUAL PROGRAM 0 No. Program
MAX OUPUT CURRENT 100 mA Digital Display for CH-1
MAX OUPUT CURRENT 100 mA Digital Display for CH-2
MAX OUPUT VOLTAGE 100V (Peak to Peak)
MEDIUM FREQUENCY 2 KHz & 4 KHz
BASE AMF 1-150 Hz with Digital Display
Spectrum 0-150 Hz with Digital Display
THERAPY MODE 4P, 4PV, 2P
VECTOR MODE 2PL, 4PL, 4PT, 4PNL
TENS PLANE / BURST 1-250 Hz / 1 to 5 Hz
DIGITAL TIMER 1 ~60 Minutes Adjustable
Interferential TherapyCode: LCS 150
interferential therapy
SPECIFICATIONS
Operating Voltage 140-270V 50Hz
Absorption 46-Watts Max
Fuses 1 Amp
Room Temperature 100 C to 400 C
Moisture 10% to 80%
Preset 50 program in Preset Programs
Program 100 Create Programs
Program Cable & Electrode Test Programs
Max. Output Current 100mA Digital Display for CH-1
Max. Output Current 100mA Digital Display for CH-2
Max Output Voltage 100V (Peak to Peak)
Medium Frequency 2 KHz& 4 KHz
Base AMF 0-250 Hz with Digital Display
Spectrum 0-250 Hz with Digital Display
Therapy Mode 4P, 4PV, 2P
Wave shape Tra, Tri, Rec.
Vector Mode 2PL, 4PL, 4PT, 4PNL
Digital Timer 1 to 99 Minutes adjustable
Patient Safety Available
RUSSIAN CURRENT
Medium Frequency 2.5 KHz
Base AMF 0-200 Hz with Digital Display
Spectrum 0-200 Hz with Digital Display
DIADYNAMIC CURRENT
Current Mode MF, DF, CP, LP
Low Frequency 50Hz & 100Hz
Interferential Therapy (LCD)Code: LCS 151
interferential therapy lcd model
SPECIFICATIONS
Operating Voltage 140-270V 50Hz
Absorption 46-Watts Max
Fuses 1 Amp
Room Temperature 100 C to 400 C
Moisture 10% to 80%
Preset 50 program in Preset Programs
Program 100 Create Programs
Program Cable & Electrode Test Programs
Max. Output Current 100mA Digital Display for CH-1
Max. Output Current 100mA Digital Display for CH-2
Max Output Voltage 100V (Peak to Peak)
Medium Frequency 2 KHz& 4 KHz
Base AMF 0-250 Hz with Digital Display
Spectrum 0-250 Hz with Digital Display
Therapy Mode 4P, 4PV, 2P
Wave shape Tra, Tri, Rec.
Vector Mode 2PL, 4PL, 4PT, 4PNL
Digital Timer 1 to 99 Minutes adjustable
Patient Safety Available
RUSSIAN CURRENT
Medium Frequency 2.5 KHz
Base AMF 0-200 Hz with Digital Display
Spectrum 0-200 Hz with Digital Display
DIADYNAMIC CURRENT
Current Mode MF, DF, CP, LP
Low Frequency 50Hz & 100Hz
Interferential Therapy + Tens + MSCode: LCS 152
interferential therapy with tens and ms
SPECIFICATIONS
Operating Voltage 140-270V 50Hz
Absorption 50-Watts Max
Fuses 1 Amp
Room Temperature 100 C to 400 C
Moisture 10% to 80%
Preset memory 100 program in Preset Programs
User memory 100 programs in User Programs
Probe test Cable & Electrode Test Programs
Max. Output Current 100mA Digital Display for CH-1
Max. Output Current 100mA Digital Display for CH-2
Max Output Voltage 100V (Peak to Peak)
Medium Frequency 2 KHz& 4 KHz
Base AMF 0-250 Hz with Digital Display
Spectrum 0-250 Hz with Digital Display
Therapy Mode 4P, 4PV, 2P
Wave Shape TRA, TRI, REC
Vector Mode 2PL, 4PL, 4PNL, 4PT
Digital Timer 1 to 99 Minutes adjustable
TENS
Tens Mode Continuous / Burst
Tens frequency 1to250Hz stapes of 1Hz
Tens Burst 1 to 100Hz adjustable
Digital Timer 1 to 99 Minutes adjustable
MUSCLE STIMULATOR
GALVANIC Plane & Interrupted
FARADIC Plane Faradic & Surge Faradic
Pulse Rate/ frequency 0.5,1,3 Hz
Pulse Type Rectangular, Triangular
Pulse Duration (Gal) 0.1,0.3,1,3,10,30,100,300 M.Sec
Pulse Duration (Far) 50 Hz (0.7 Msec.)
On time (faradic) 1 to 10 sec
MUSCLE STIMULATOR
Medium Frequency 2.5 KHz
Base AMF 0-200 Hz with Digital Display
Spectrum 0-200 Hz with Digital Display
DIADYNAMIC CURRENT
Current Mode MF, DF, CP, LP
Low Frequency 50Hz & 100Hz