Interferential Therapy Machine ( Eco Models)

The basic principle of electrotherapy Interferential Therapy (IFT) is to utilise the strong physiological portable interferential effects of low frequency (<250pps) electrical stimulation of nerves without the associated painful and somewhat unpleasant side effects sometimes associated with low frequency stem.

To produce low frequency effects at sufficient intensity at depth, patients can experience considerable discomfort in the superficial tissues (i.e. the skin). This is due to the impedance of the skin being inversely proportional to the frequency of the stimulation. In other words, the lower the stimulation frequency, the greater the impedance to the passage of the current & so, more discomfort is experienced as the current is �pushed� into the tissues against this barrier. The skin impedance at 50Hz is approximately 3200* whilst at 4000Hz it is reduced to approximately 40*. The result of interferential machines applying a higher frequency is that it will pass more easily through the skin, requiring less electrical energy input to reach the deeper tissues & giving rise to less discomfort.

Application

The clinical application of IFT therapy is based on peripheral nerve stimulation (pps) data, though it is important to note that much of this information has been generated from research with other equipments, and its transfer to IFT is assumed rather than proven. There is a lack of Interferential Therapy specific research compared with other modalities (e.g. TENS).

Interferential Therapy Eco ModelCode: LCS 150 eco
interferential therapy
SPECIFICATIONS
Dimension (L*H*D) 275mm, 85mm, 210mm
Weight 1.2 Kg. Approx.
Operating Voltage 110-270V 50Hz
Absorption 46-Watts Max
Fuses 1 Amp
ROOM TEMPERATURE 10° to 40° C
Moisture 10% to 80%
Preset Program 50 Programs
Customize Program 99 Create Programs
Probe Test Cable & Electrode Test
Max. Output Current 100mA Digital Display for CH-1 & CH-2
Max Output Voltage 100V (Peak to Peak)
Medium Frequency 2 KHz& 4 KHz
Base AMF 0-250 Hz
Spectrum 0-250 Hz
Therapy Mode 4P, 4PV, 2P
Wave Shape TRA, TRI, REC.
Vector Mode 2PL, 4PL, 4PT, 4PNL
Treatment Time 01 to 99 Minutes adjustable
Patient Safety Available
RUSSIAN CURRENT
Medium Frequency 2.5 KHz
Base AMF 0-200 Hz
Spectrum 0-200 Hz
DIADYNAMIC CURRENT
Current Mode CP, LP, DF, MF
Low Frequency 50Hz & 100Hz
Interferential Therapy+Tens Eco ModelCode: LCS 151 eco
interferential therapy lcd model
SPECIFICATIONS
Dimension (L*H*D) 275mm, 85mm, 210mm
Weight 1.2 Kg. Approx.
Operating Voltage 100-270V 50Hz
Absorption 46-Watts Max
Fuses 1 Amp
Room Temperature 10° to 40° C
Moisture 10% to 80%
Preset Program 50 Programs
Customize Program 99 Create Programs
Probe Test Cable & Electrode Test
Max. Output Current 100mA Digital Display for CH-1 & CH-2
Max Output Voltage 100V (Peak to Peak)
Medium Frequency 2 KHz& 4 KHz
Base AMF 0-250 Hz
Spectrum 0-250 Hz
Therapy Mode 4P, 4PV, 2P
Wave Shape TRA, TRI, REC.
Vector Mode 2PL, 4PL, 4PT, 4PNL
Treatment Time 01 to 99 Minutes adjustable
Patient Safety Available
RUSSIAN CURRENT
Medium Frequency 2.5 KHz
Base AMF 0-200 Hz
Spectrum 0-200 Hz
DIADYNAMIC CURRENT
Current Mode CP, LP, DF, MF
Low Frequency 50Hz & 100Hz
TENS
TENS Mode Continuous / Burst
TENS Frequency 1 to 250Hz Steps of 1 Hz
TENS Burst 1 to 100Hz Adjustable
Treatment Time 01 to 99 Minutes Adjustable
Maz. Output Current 100mA